51kg m weight per 1 000.
Gemini roof tiles gauge.
Forticrete s single lap tiles need to be gemini minislate senator and v2 will need to be screwed and clipped and the corners will need to be mitred with a lead detail.
With its double cambered design this interlocking concrete tile gives the appearance of traditional plain tiles when laid.
This innovative product assists both in reducing the build cost and the environmental impact of the project by lowering the amount of quarried aggregate used and haulage movement per laid m.
You can fit gemini on roof pitches as low as 25 º with confidence.
The batten gauge is not the same either side of the valley.
285mm gauge 17 5 tiles m recommended pitch may be influenced by certain weight at 285mm gauge.
18 1 slates m weight at 175mm gauge.
Minimum 175mm maximum 190mm linear cover of one slate.
Gemini roof tile technical data size overall.
Because of gemini s design fewer tiles are required to cover the same area as a conventional double lapped plain tile.
Only 16 3 tiles per m2 60 for plain tiles 20 fixing labour savings in comparison to plain tiles 30 reduction in weight 42 timber savings on roof battens 6 timber savings on roof trusses lays to lower pitches 22 5 plain tiles 35.
Gemini are strong lightweight roof tiles which are designed to replicate the aesthetics of plain tiles.
How to tile a roof if you would prefer to read how to tile a roof and see more help please visit this link unless you found this video via my website.
Where it is allowed to ventilate out between the gaps in the roof tiles or slates.
Simple to lay and single lapped.
22 5 to 29 pitch 16 6 m2 80mm min.
Gemini is an award winning twin interlocking plain tile which is suitable for pitches down to 22 5 and is available in 11 colours.
16 6 slates m 175mm gauge.
This innovative interlocking tile is 270mm x 330mm overall with a central groove to give the appearance of two plain tiles when laid side by side.
The batten gauge varies depending on pitch you are installing at.
M m positioning of irst batten.
Headlap 190mm max.
The tiles are suitable for pitches down to 22 5º for new or re roof projects.
Gemini double cambered plain tile appeal at pitches down to 22 5.
Clients include all of the major national house builders local authorities housing associations clinical commissioning groups and care home providers as well as numerous commercial projects.
3 0 tonnes minimum batten size.
47mm x 35mm battens required at 175mm gauge.
316mm covering capacity nett at 190mm gauge.